GSP Lock
Battery Installation
You Will Need:
-
9-volt alkaline battery (Duracell®, Energizer®)
Step 1 – Open Slide Door
Open the Slide door located on the bottom of the keypad.
Step 2 – Remove Old Battery
Gently pull the battery connector and wires down.
Step 3 – Connect New Battery
Attach the new battery (9-volt alkaline only) to the connector.
Be careful not to pull on the wires.
Step 4 – Reinsert Battery
Carefully insert the battery back into the keypad until the wires are no longer exposed and slide the door closed.
Lock Instructions
FACTORY SET COMBINATION: 1 – 2 – 3 – 4 – 5 – 6
IMPORTANT: ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN AND BOLTS EXTENDED.
Step 1
Enter zero (0) six times. (You will hear a double beep, indicating program mode).
Step 2
Enter your existing six (6) digit combination one time. (You will hear a double beep)
Step 3
Enter your NEW six (6) digit combination. (You will hear a double beep)
Step 4
Enter your new six (6) digit combination again.
Step 5
Wait approximately 10 seconds and then enter your new combination, and then rotate the handle to open the safe door.
Step 6
Test lock operation several times before closing the door.